Global Global Algérie Français Algeria English Angola Português Angola English Argentina Español Argentina English Australia English Austria Deutsch Austria English Azerbaijan English Azerbaijan Русский Bahrain English Bangladesh English Belgium English Belgium Français Belgium Nederlands Brazil Português Brazil English Bulgaria български Bulgaria English Cameroon English Cameroon Français Canada English Canada Français Chile Español Chile English China 中文 China 日本語 China English Colombia Español Colombia English Croatia English Czech Republic Čeština Czech Republic English Denmark English Djibouti English Ecuador Español Ecuador English Egypt English Estonia English Ethiopia English Finland Suomi Finland English France Français France English Georgia English Georgia Русский Germany Deutsch Germany English Ghana English Greece Ελληνικά Greece English Guatemala Español Guatemala English Hong Kong, China English Hong Kong, China 中文 Hungary Magyar Hungary English India English Indonesia English Iraq English Ireland English Italy Italiano Italy English Ivory Coast Français Ivory Coast English Japan 日本語 Japan English Jordan English Kazakhstan Русский Kazakhstan English Kenya English Kuwait English Kyrgyzstan Русский Kyrgyzstan English Latvia English Lithuania English Malaysia English Mauritius English Mauritius français (Maurice) Mexico Español Mexico English Moldova Română Moldova English Mongolia English Morocco English Morocco Français Mozambique Português Mozambique English Netherlands Nederlands Netherlands English New Zealand English Nigeria English Norway English Oman English Pakistan English Paraguay Español Paraguay English Peru Español Peru English Philippines English Poland Polski Poland English Portugal Português Portugal English Qatar English Republic of Korea 한국어 Republic of Korea English Romania Română Romania English Saudi Arabia English Serbia Српски Serbia English Singapore English Slovakia English Slovenia English South Africa English Spain English Spain Español Sri Lanka English Sweden English Switzerland Deutsch Switzerland Français Switzerland Italiano Switzerland English Tanzania English Thailand ไทย Thailand English Togo English Togo Français Tunisia English Tunisia Français Türkiye Türkçe Türkiye English Turkmenistan Русский Turkmenistan English Ukraine Українська Ukraine English United Arab Emirates English United Kingdom English Uruguay Español Uruguay English USA English Uzbekistan English Uzbekistan Русский Vietnam Tiếng Việt Vietnam English

Intergranular Corrosion Testing Methods: Standards, Practices, and Evaluation Procedures

Intergranular corrosion (IGC) testing is a critical quality control procedure used to evaluate the susceptibility of stainless steels, nickel alloys, and other metals to localized attack along grain boundaries. This technical article provides a comprehensive overview of internationally recognized intergranular corrosion testing methods, including ASTM A262, ASTM A763, ASTM G28, ISO 3651, GB/T 4334, and JIS G0571-G0575, covering sample requirements, test procedures, evaluation criteria, and industrial applications. Whether you need material acceptance testing, welding procedure qualification, or failure analysis, this guide explains how accredited third-party laboratories perform these essential corrosion tests.

Technical Overview

Intergranular corrosion (IGC) is a localized form of corrosion that preferentially attacks the grain boundaries of a metal, while the bulk of the grains remains largely unaffected. In austenitic stainless steels and nickel-chromium alloys, the most common cause is sensitization: when the material is exposed to temperatures between approximately 425°C and 815°C (for example, during welding, slow cooling after heat treatment, or service at elevated temperatures), chromium carbides (Cr23C6) precipitate at the grain boundaries. This precipitation depletes the chromium content in the zones adjacent to the boundaries below the level required to maintain a stable passive film, leaving those areas vulnerable to accelerated corrosive attack.

Because intergranular corrosion can proceed with little visible evidence on the surface while severely degrading mechanical strength, ductility, and structural integrity, standardized laboratory testing is essential for material qualification, welding procedure qualification, and failure investigation. The dominant international standards include ASTM A262 (austenitic stainless steels), ASTM A763 (ferritic stainless steels), ASTM G28 (nickel-rich chromium-bearing alloys), ASTM G67 and ASTM G110 (aluminum alloys), ISO 3651-1 and ISO 3651-2, GB/T 4334, and JIS G0571 through G0575. These standards define the test solutions, exposure durations, specimen preparation requirements, and acceptance evaluation methods used by accredited third-party laboratories worldwide.

Testing Samples

Austenitic Stainless Steels

The largest group of samples tested for intergranular corrosion susceptibility includes austenitic grades such as 304, 304L, 316, 316L, 316Ti, 321, 347, 310S, and 904L, in accordance with ASTM A262 or ISO 3651-2. Both solution-annealed and sensitized conditions may be evaluated, and extra-low-carbon (L grades) and stabilized grades (titanium- or niobium-stabilized) are frequently tested to verify their resistance after welding or thermal exposure.

Ferritic and Duplex Stainless Steels

Ferritic stainless steels such as 430, 434, 436, 444, and 446 are tested under ASTM A763 (Practices W, X, Y, and Z) or JIS G0575, since the classical austenitic test practices are not always appropriate for their metallurgy. Duplex stainless steels such as 2205 and 2507 may also be assessed for grain boundary attack and secondary phase precipitation, typically using practices adapted from ASTM A262 Practice B or ISO 3651-2 Method B.

Nickel-Based Alloys

Wrought, chromium-bearing nickel alloys, including Alloy 400 series, Alloy 600, Alloy 625, Alloy 800, Alloy 825, and Alloy 20, are tested according to ASTM G28 Method A (ferric sulfate-sulfuric acid) or Method B (mixed acid containing nitric and hydrofluoric acids with ferric chloride). These alloys are widely used in chemical processing and pollution control equipment where grain boundary attack from improper heat treatment must be excluded.

Aluminum Alloys

5xxx series aluminum-magnesium alloys used in marine and structural applications can suffer sensitization through beta-phase (Al3Mg2) precipitation at grain boundaries. ASTM G67 (nitric acid mass loss test, NAMLT) and ASTM G110 (etching and metallographic examination) are the principal methods for evaluating this susceptibility.

Product Forms and Configurations

  • Plates, sheets, and strips
  • Bars, rods, and wires
  • Seamless and welded pipes and tubes
  • Forgings and castings
  • Welded joints, weld overlays, and claddings
  • Finished components and hardware after fabrication or heat treatment

Testing Items

Intergranular corrosion testing programs typically include the following evaluation items, depending on the selected standard and product specification:

  • Susceptibility to intergranular attack in a specific boiling acid environment
  • Corrosion rate calculated from mass loss (expressed in mm/y, µm/h, or mils per month)
  • Bend test after acid exposure to reveal intergranular cracking or fissuring
  • Metallographic examination for ditch structure, grain dropping, and attack depth
  • Classification of etch structures (for example, step, dual, or ditch structures in the oxalic acid etch screening test)
  • Electrochemical reactivation parameters such as reactivation charge density and reactivation ratio in EPR testing
  • Verification of stabilizing or solution-annealing heat treatment effectiveness
  • Weld heat-affected zone (HAZ) sensitization assessment

Testing Methods

ASTM A262 – Austenitic Stainless Steels

ASTM A262 is the most widely referenced practice for detecting susceptibility to intergranular attack in austenitic stainless steels and comprises several practices with different severity levels and target corrosion mechanisms:

  • Practice A – Oxalic Acid Etch Test: A rapid electrochemical screening test in which the specimen is etched in 10% oxalic acid at ambient temperature and examined microscopically. Ditch structures indicate potential susceptibility and require confirmatory testing; step and dual structures generally indicate acceptable resistance. It is a screening method only and cannot be used for final acceptance.
  • Practice B – Ferric Sulfate–50% Sulfuric Acid Test: A 120-hour boiling test (commonly known as the Streicher test) that measures chromium depletion. Results are evaluated by mass loss converted to a corrosion rate, compared against acceptance limits set by the product specification.
  • Practice C – Nitric Acid Test (Huey Test):strong> A 240-hour test consisting of five consecutive 48-hour boiling periods in 65% nitric acid. It is particularly sensitive to sigma phase and molybdenum-containing intergranular phases, and is commonly required for alloys intended for nitric acid service.
  • Practice E – Copper–Copper Sulfate–16% Sulfuric Acid Test (Strauss Test): A 24-hour boiling test in which specimens are immersed in the acid solution in contact with copper shot or turnings. Evaluation is by bend test, with intergranular cracking indicating sensitization. It primarily detects chromium carbide precipitation.
  • Practice F – Copper–Copper Sulfate–50% Sulfuric Acid Test: A 96-hour boiling test for molybdenum-bearing austenitic stainless steels (such as 316 and 317), combining mass-loss evaluation with sensitivity to chromium depletion in molybdenum-containing grades.

ASTM A763 – Ferritic Stainless Steels

ASTM A763 provides Practices W, X, Y, and Z, which apply ferric sulfate-sulfuric acid, ferric sulfate-50% sulfuric acid, copper-copper sulfate-16% sulfuric acid, and nitric acid exposures respectively, adapted to the sensitization behavior of ferritic grades.

ASTM G28 – Nickel-Rich, Chromium-Bearing Alloys

ASTM G28 Method A exposes specimens to a boiling ferric sulfate-50% sulfuric acid solution for 24 or 120 hours, depending on the alloy, with acceptance based on the calculated corrosion rate. Method B uses a more aggressive boiling mixed acid (ferric chloride, nitric acid, and hydrofluoric acid) for 24 hours and is applied to alloys such as 625, C-276, and other high-performance materials.

ISO 3651-1 and ISO 3651-2

ISO 3651-1 specifies the general principles, while ISO 3651-2 defines the specific test media: a 16% sulfuric acid-copper sulfate solution with metallic copper contact, a 35% sulfuric acid solution, a 50% sulfuric acid-ferric sulfate solution, and a 50% sulfuric acid-copper sulfate solution. Evaluation combines mass loss and bend testing.

GB/T 4334 and JIS G0571–G0575

The Chinese national standard GB/T 4334 series mirrors the major international practices, offering methods in sulfuric acid-copper sulfate (with and without copper contact), ferric sulfate-sulfuric acid, nitric acid, and oxalic acid etching. The Japanese standards JIS G0571 through G0575 provide equivalent procedures for the Japanese market, ensuring global harmonization of acceptance criteria.

ASTM G108 – Electrochemical Potentiokinetic Reactivation (EPR)

EPR testing is a rapid, quantitative electrochemical method for evaluating the degree of sensitization in austenitic stainless steels such as 304 and 304L. Single-loop and double-loop variants measure the reactivation charge density or the ratio of reactivation to activation currents, providing a numerical degree of sensitization without the long boiling acid exposures required by chemical immersion tests.

Evaluation of Results

Regardless of the method, results are interpreted through one or more of the following criteria: (1) corrosion rate from mass loss, where the rate is calculated from specimen dimensions and exposure time and compared against specification limits; (2) a 180-degree bend test over a defined mandrel, where visible cracking or fissuring on the tension surface indicates intergranular attack; and (3) metallographic cross-section examination to measure attack depth, confirm grain dropping, or classify etch structures. The applicable acceptance criteria are established by the governing product specification, purchase order, or design code.

Applications

Intergranular corrosion testing is applied across a wide range of industries and scenarios:

  • Chemical and petrochemical processing equipment: reactors, columns, piping, and vessels exposed to corrosive acids
  • Oil and gas: refinery equipment, sour service components, and offshore platform hardware
  • Power generation: nuclear plant cooling circuits, steam generators, condenser tubing, and boiler components
  • Pharmaceutical and food processing: hygienic piping, sanitary fittings, and vessels requiring corrosion-resistant surfaces
  • Pulp and paper: digesters and bleaching plant equipment
  • Marine engineering: seawater cooling systems, fasteners, and structural components
  • Aerospace: aluminum-magnesium structural alloys assessed for sensitization
  • Material acceptance and incoming inspection of mill products prior to fabrication
  • Welding procedure qualification and welder performance verification
  • Heat treatment validation, including solution annealing and stabilization treatments
  • Failure analysis and root cause investigation of service cracking incidents

FAQ

What is the difference between the Huey, Strauss, and Streicher tests?

The Huey test (ASTM A262 Practice C, boiling 65% nitric acid for 240 hours) is highly sensitive to sigma phase and is preferred for nitric acid service. The Strauss test (Practice E, boiling copper-copper sulfate-16% sulfuric acid for 24 hours with copper contact, evaluated by bend test) primarily detects chromium carbide precipitation. The Streicher test (Practice B, boiling ferric sulfate-50% sulfuric acid for 120 hours) measures chromium depletion by mass loss. The correct choice depends on the alloy, the metallurgical phenomenon of concern, and the governing specification.

When should the oxalic acid etch test be used?

The oxalic acid etch test (ASTM A262 Practice A) is a rapid screening tool that takes only minutes. It classifies the etch structure as step, dual, or ditch. Specimens showing step or dual structures may be accepted for certain grades without further testing, while ditch structures require a confirmatory hot-acid test. It is never used alone for final acceptance.

What specimen preparation is required?

Typical specimens are cut to the dimensions specified by each standard (commonly around 25–30 mm by 50–100 mm for flat products), with surfaces ground to a uniform finish, deburred, degreased, cleaned, dried, and weighed to the required precision. Welded specimens must retain the weld, heat-affected zone, and base metal so that all regions are exposed to the test solution. Dimensional measurement of surface area is required for corrosion rate calculations.

Can sensitizing heat treatment be applied before testing?

Yes. Some specifications require a laboratory sensitizing heat treatment (for example, heating within the 650–675°C range followed by controlled cooling) before exposure, in order to evaluate the material's intrinsic susceptibility under worst-case thermal conditions. Whether sensitization is applied, and its exact parameters, must be defined by the purchase specification or test request.

How long does an intergranular corrosion test take?

Duration depends on the method: the oxalic acid etch takes less than one hour, the Strauss test requires 24 hours of boiling, ASTM G28 Method A requires 24–120 hours, the Streicher test requires 120 hours, and the Huey test requires 240 hours spread across five 48-hour periods. Additional time must be allowed for specimen preparation, post-exposure bend testing, metallography, and reporting.

What results constitute a failure?

A test is generally considered failed if the calculated corrosion rate exceeds the limit in the product specification, if the post-exposure bend specimen exhibits intergranular cracks or fissures visible at a defined magnification, or if metallographic examination reveals grain boundary attack or grain dropping beyond the acceptance depth. Accredited third-party laboratories report all measured values and observations, but the final accept/reject decision is made against the criteria of the governing standard or specification.

Why is intergranular corrosion testing important after welding?

Welding creates thermal cycles that pass portions of the heat-affected zone through the sensitization temperature range, potentially forming chromium carbides at grain boundaries. Testing cross-weld specimens verifies that the base metal, filler metal, and welding procedure together provide adequate resistance to intergranular attack in service, and it is a routine requirement for welding procedure qualifications in corrosion-critical applications.